Electrical Glove Testing Equipment
Here is a video of our ejection style glove tester.
Electrical glove testing equipment. Check in wash and preliminarily inspection of insulating materials. Additionally 1910 137 provides specific design care and use requirements for rubber electrical protective equipment. Rubber insulated electrical glove testing. Again any item that fails the electrical test is rejected and immediately rendered unusable.
This quick video shows that after a fault in any glove is detected the machine tells you which glove is flawed and then ejects the probe from that particular glove. Burlington safety laboratory is your source for linemen s protective equipment. Insulating gloves and sleeves must be rated for the voltage to which a worker will be exposed phase to ground or phase to phase and marked to indicate their rating. How often should i test my voltage rated gloves.
Dival is your one stop shop for all of your arc flash electrical glove and ppe needs. Jm test systems is fully accredited for testing high voltage rubber protective goods. Our test facility offers comprehensive compliance testing for rubber insulated electrical gloves. Immediately following the failure the machine automatically starts ramping up voltage to test the rest of the gloves on that.
Our rubber testing lab provides electrical glove testing services to astm d120 astm f496 standards. Check out a few of our popular units here. A complete record of the testing is documented on a test result sheet. We not only supply electrical gloves ppe we inspect and test them too.
Testing of high voltage gloves should be done every 6 months. All gloves tested by jm test systems include a detailed testing report. Gloves sleeves and blankets then undergo an electrical test as specified by the class rating of the item and the astm and osha standards maximum 40kv a c. Combination glove sleeve blanket line hose testing equipment.
We have been serving electric utilities telecommunications companies railroads power line contractors and industrial accounts for more than 30 years. Misinterpreting the rules requiring dielectric testing of electrical insulating gloves and the corresponding expiration dates can be easy to do use article130 7 c 7 nfpa 70e as a reference we add clarity to this commonly misinterpreted safety requirement. Electrical testing of insulated aerial lift devices. What we offer with your lineman gloves.
Whether it s equipment you need to get the power up and running or equipment you need to test the equipment you need to get the power up and running we ve got you covered.