Duct Leakage Test Results
Test to as a leakage specifi cation.
Duct leakage test results. The test may be performed prior to close in or at final inspection. Start a free trial now to save yourself time and money. Our duct leakage test results are in. Duct leakage testing 2017 dc energy conservation code 2015 iecc r403 3 3 duct testing mandatory.
The test results shall be provided to the building official and the homeowner. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating ventilating and air conditioning hvac ductwork. Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in rs 33. In both cases the requirements are the same.
Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow. Figure 5 1l from the 2012 smacna hvac air duct leakage test manual shows the allowable leakage as a function of duct leakage classification and static pressure in the duct. The system will need to achieve a leakage rate of less than 4 cfm cubic feet per minute per 100 square feet of the home.
Rough in test less than 4 cfm per 100 sq ft which for my house is about 160 cfm if the air handler is included in the leakage test. Mcgill airflow often gets specifi cations stating that the leakage class for rectangular and round ductwork will be in accor dance with the smacna table 4 1 for a 3 inch water gauge wg supply duct system thus allowing the rectangular duct leakage class to be 12 and the round and fl at oval duct leakage. Available for pc ios and android. Fill out securely sign print or email your duct leakage test report tra green instantly with signnow.
A duct leakage test duct testing can be performed at rough in before drywalling or post construction. Us duct leakage testing ri trequirements smacna duct class 1 2 inwg 3 inwg 4 6 10 inwg seal class cb a sli t transverse joints seams sealing applicable ransverse joints only asvese joints and seams jo s sea s and all wall penetrations leakage class c l cfm leakage per 100 ft2 1 in h 2 o rectangular. The duct blaster is used to quantify the leakage rate of the duct system. The energy final inspection will not be complete without a passing test result.
The most secure digital platform to get legally binding electronically signed documents in just a few seconds. Testing shall be conducted by an approved third party. However our local utah code has a carve out allowing 7 cfm per 100 sq ft. Duct leakage test report.
Ducts with less than 40 linear feet in unconditioned spaces.